🔌 1. How do I configure BMS communication with lithium batteries?EASUN SMG II 11KW supports RS485 communication with a variety of BMS systems such as Pylontech, JK, Jikong, and Daly.
Pylontech BMS: Select battery type “Li2” in the inverter menu and set BMS to “Pylon RS485”.
Daly BMS: Some users report success using “Li4” and setting Daly BMS to "Growatt" protocol.
JK BMS: It is recommended to use “Li2” and ensure correct wiring.
Note: Wiring methods may vary depending on the BMS brand. Please refer to the connection diagrams or consult technical support.
Click to check how to connect to Easun Battery⚡ 2. How do I know If this inverter is compatible with my solar panels ?
According to the inverter's specification table, the solar input current is 18A × 2, which means each MPPT can handle a maximum of 18A.
The optimal voltage range for the MPPT is 380–430V, and it should not exceed 450V.
Based on this information, when you review the specifications of your solar panels, you should ensure that—whether connected in series or parallel—the total voltage or current connected to each MPPT input does not exceed these limits.
☀️ 3. What is the minimum PV voltage required to start the inverter?The MPPT controller requires at least 120VDC PV input to start, but a recommended input of 250VDC or higher is suggested to ensure stable power output under load.
🛠️ 4. How can I fix the issue of the LCD screen flickering?Some users have reported flickering on the inverter's display.
A common solution is to connect an X2-class capacitor in parallel between PV+ and PV- to stabilize voltage fluctuations.
⚠️ This operation requires electrical knowledge. Please consult a professional.
🔄 5. Does the inverter support parallel operation?No, the EASUN SMG II 11KW does not support parallel connection.
If you need parallel functionality, consider models in the EASUN SMW series that support this feature.
📶 6. How does the WiFi monitoring work?The inverter has a built-in WiFi module and can be monitored via a mobile app.
Download the recommended monitoring app and follow the instructions in the user manual.
Note: Data updates from the WiFi module may occur at 5-minute intervals.
🔋 7. Can the inverter run without a battery?Yes, EASUN SMG II 11KW supports batteryless operation.